FCB100
Overview
With no up or downstream piping requirements the compact flowmeters can be installed in the tightest spaces, enabling applications not possible before.
The FCB100 series delivers:
- Superior accuracy and speed for filling applications
- Full parameter access with up to 115 kBaud
- Aluminum housing or all stainless steel solution
- DTM based diagnostic and operability functions
The sensor delivers:
- Multivariable measurement of mass flow, density and temperature in one device
- Low pressure drop save 25 % on pump energy costs compared to other brands
- Wide measurement span in a single meter
FCB150 adds:
- DensiMass: High accuracy concentration measurement, watercut and net-oil computing as well as net-mass and net-volume measurement
- FillMass: Filling application software with integrated precounter, over- and underfill correction and contact output for valve control
Data
General specifications:
- Nominal sizes / measuring ranges
- – DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
- – DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
- – DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
- – DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
- – DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
- – DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h)
- Ex approvals
- – ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2
- Wetted materials
- – 1.4404 / 1.4435 (316L) or Hasteloy C
- Accuracy for liquids
- FCB130
- – Mass and volume: 0.4 % o. r. / 0.25 % o. r.
- – Density: 10 g/l
- FCB150
- – Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
- – Density: 2 g/l or 1 g/l
- Measuring medium temperature
- FCB130
- – -50 to 160 °C (-58 to 320 °F)
- FCB150
- – -50 to 205 °C (-58 to 400 °F)
- Outputs
- – 2 digital out (pulse, frequency, contact)
- – Modbus
- Power supply
- – 11 to 30 V DC