Overview

Precise and dynamic direct mass flow measurement of gases for OEM applications.

  • High-grade thermal sensor elements
  • – superior long-term stability
  • – effective sensor element protection frame with flow conditioning properties
  • SmartSensor solution
  • – Meter intelligence located at the sensor
  • – all digital solution
  • – reduced wiring costs with industry standard connection cables
  • – long cable distances are possible
  • SensorApplicationMemory
  • – Plug and play electronics replacement
  • – Redundant data storage for maximum data security
  • ABB common electronic concept
  • – MODBUS communication interface
  • – Multiple 32-bit processor structure
  • – full digital heating circuit control
  • – dynamic temperature compensation
  • ApplicationSelector
  • – Adaption of the characteristic application parameters on site
  • – choice between up to two applications (FMT230)
  • – choice between up to eight applications (FMT250)
  • – setup new applications without the need for recalibration (FMT250)
  • VeriMass onboard verification and diagnostics
  • – Fingerprint based SensorCheck to verify the integrity of the thermal sensor elements
  • – continuous health check of the meter
  • – parameter plausibility check


Data

General specifications:

  • Measuring media
  • – Air, Nitrogen, Oxygen, Carbon dioxide, Methane, Hydrogen, Natural Gas, Biogas, Helium, Argon, Propane, Ethane, Ethene, Butane, Ammonia, more gas types on request
  • FMT230 measuring accuracy for air under reference conditions
  • – ±1.2 % of rate within 10 … 100 % of measuring range
  • – ±0.12 % full scale within 1 … 10 % of the measuring range
  • FMT250 measuring accuracy for air under reference conditions
  • – ±0.6 % of rate ±0.05 % full scale
  • FMT250 measuring accuracy for gases under reference conditions
  • – with optional process gas calibration 
  • – ±1.6 % of rate ±0.1 % full scale
  • Integral mount transmitter design
  • – single compartment transmitter housing
  • Measuring medium temperature
  • – -25 … 150 °C (-13 … 302 °F)
  • Ambient temperature
  • – -20 … 70°C ( -4 … 158°F)
  • – optional -40 … 70 °C (-40 … 158 °F)
  • – optional -50 … 70 °C (-58 … 158 °F)
  • Supply Voltage
  • – 24 V DC ±20 %
  • Process adaption via pipe components in different designs
  • – partial measuring sections (DN 25 …DN 100)
  • – wafer design pipe components (DN 40 … DN 200)
  • – Weld-on adapters (DN 100 … DN 3000)
  • FMT250 added functionality
  • – high accuracy calibration
  • – process gas calibration 
  • – extended Measuring range 
  • – high medium temperature up to 300 °C (572 °F) 
  • – filling application software
  • – ApplicationSelector with up to 8 applications
  •   …with up to 4 customer set applications
  •   …with selectable gas type
  •   …with selectable pipe inner diameter


BİZİMLE İLETİŞİME GEÇ!