Overview

Pressductor PillowBlock horizontal load cells are ideal in applications characterized by low tension levels, heavy rolls and high operating speeds - a scenario often encounted in the paper industry.

The PillowBlock comes in three versions: The standard version, PFTL 101A/B, is often used for accurate measurement in the paper industry, for instance paper machines, calenders, coaters and winders.


For web tension measurement in dryer sections in paper machines, the mill duty version, PFTL 101AE/BE, is recomended. This version has a fixed connection cable and a degree of protection of IP 66, which provides accurate and reliable measurement with long service life.


The acid resistant version, PFTL 101AER/BER, is designed for the wet end of the paper machines and has a degree of protection of IP 66/67

.

Data

Properties PFTL101A/AE/AER

Nominal load

(rated capacity) kN 0.5 1.0 2.0

Lbs. 112 225 450

Permitted load

Transverse direction kN 5.0 10.0 10.0

Lbs. 1125 2250 2250

Overload capacity

Measurement direction kN 2.5 5.0 10.0

Lbs. 563 1125 2250

Deflection mm 0.015 0.015 0.015

1/1000 in. 0.6 0.6 0.6

Spring constant kN/mm 32 65 130

1000 Lbs./inch 183 371 743


Properties PFTL101B/BE/BER

Nominal load

(rated capacity) kN 2.0 5.0 10.0 20.0

Lbs. 450 1125 2250 4500

Permitted load

Transverse direction kN 30.0 30.0 30.0 40.0

Lbs. 6750 6750 6750 9000

Overload capacity

Measurement direction kN 10.0 25.0 50.0 80.0

Lbs.2250 5625 11250 18000

Deflection mm 0.015 0.015 0.015 0.015

1/1000 in. 0.6 0.6 0.6 0.6

Spring constant kN/mm 130 325 650 1300

1000 Lbs./inch 743 1857 3715 7430